High-Quality Speciality Electronic Water Descaler Machine

Model NO.: CLDC
Bacterial Killing: More Than 95percent
Algae Removing: More Than 95percent
Trademark: peide
Transport Package: Wooden Cases
Specification: ISO 9001
Origin: China
Model NO.: CLDC
Bacterial Killing: More Than 95percent
Algae Removing: More Than 95percent
Trademark: peide
Transport Package: Wooden Cases
Specification: ISO 9001
Origin: China
High-quality Speciality Electronic Water Descaler Machine


Application 

The electric descaler widely used in central air conditioning system, industry chilling system, heat exchange system, boiler system, etc.
 
Product structure 

It consists of main and vice part, which can be installed together or separated. Main part is a high-frequency signal generator, vice part can transfer signal to water.
 
Working principle

1.scale resist and prevent
Based on Electromagnetic Theory, invented by Dr. Lorentz, the electric water descaler stops calcium carbonate and magnesium carbonate formation. Water absorbs electromagnetic energy, which physical structure changes and chain water molecules break into smaller single water molecule. The single water molecule covers negative and positive ion of dissolve saline, which reduces electrostatic attraction and effective collision, but increase water dipole moment and compatibility to negative and positive saline, which finally loose pipe wall scale and to remove them.

2.kill bacterial and algae 
The electromagnetic wave creates turbulence flow, which destroys cell wall's ion channel and changes cell's living ambient. Cells die as of no suitable living area. What's more, large amount of single water molecules covers dissolve oxygen, which cut microorganism oxygen demanding so that to prevent microorganism sediment formation.

3. rust resist and corrosion prevention
Oxygen molecule in water become inert oxygen as covered by singe water molecule, which cut off oxygen-demanding for mental rust. 
The electromagnetic field create "Skin-effect", which gathers negative charge inside pipeline wall. Water molecule covers positive charge, it rejects Fe ion dissolve from metal pipe. Negative charge on pipeline wall attract positive Fe ion to form Fe3O4 membrane.
Feature 
1.Make use of high-frequency electromagnetic technology in water treating, which can increase at least 30% work efficiency.
2.The technology can treat max water hardness of 700mg/L. ( in CaCO3)
3.The special alloy material can make use life time to 20years. 
4.Signal light shows electrode energy release enough or not. 
5.Extra add drain outlet, which is easy to drain scales.
 
 
Technical parameter 

1.Input power: 220V, 50HZ
2.Water hardness require: ≤700mg/L(CaCO3)
   Temperature: ≤95ºC
   Work pressure: 1.0MPa,1.6MPa
   Flow speed: ≤2.8m/s
3. Scale resist: ≥95%
    Bacterial killing: ≥95%
    Algae removing: ≥95%
    Reduce corrosion: reduce to 1/10 of origin
4. Function time: within 2 hours in after treating. Half-time is 1 hour. 
 
Compare 
 
 

No
Item Made by PEIDE Made by others company Instruction

1

Shielding mesh
 

 
Shielding mesh makes sure electrodes work separately, without any interruption 

 
 
No shied mesh

Increase efficiency 30%
2 Electrode material Alloy material Brass Life time 5-7times than brass
3 Circuit board and electrode connection way 
 
Makes use of shielding connection, it can transfer energy to electrodes fully

 
Connect directly, which will cause dis-connect after long using. No shielding design, which has interruption to other equipment.

Peide reduce the energy consumption to the lowest
4 In/outlet design Add extra guide plate No Peide design can transfer more stable electromagnetic energy
5 Transformer material Transformer works well even in severe ambient, (even in water) electric elements all imported Less ability in high temperature and high humidity ambient. Peide design can install indoor or outdoor
6 Protection setting on main part The special temperature design can ensure main part work less than 40ºC. Over 50ºC Main part life time increases 3-5times.
7 Drain design Yes No Peide design more completed.
8 Vice part inside treating  With phosphorization treating No Increase strength of magnetic field.



Model options
 

Model 
Pipe diameter A B C D
Power

Water Flow

inch
mm W T/H
CLDC-2D 2 50 500 100 280 300 25 19
CLDC-2.5D 2.5 65 500 100 280 300 25 28
CLDC-3D 3 80 500 150 330 300 50 50
CLDC-4D 4 100 500 150 330 300 50 80
CLDC-5D 5 125 600 219 340 400 70 125
CLDC-6D 6 150 680 273 350 400 70 180
CLDC-8D 8 200 800 325 470 500 80 320
CLDC-10D 10 250 850 377 530 550 120 490
CLDC-12D 12 300 920 426 560 600 210 710
CLDC-14D 14 350 970 478 560 650 250 1000
CLDC-16D 16 400 1020 530 660 700 330 1400
CLDC-18D 18 450 1090 630 730 750 410 1600
CLDC-20D 20 500 1200 720 830 800 500 1970

 Attentions
1.Water equipment should be installed before equipment that need protect. It will be better to close to pump. All recycling water should flow into water treatment equipment fist.
2.If there's no big default and scales on old system, water treatment equipment can be installed directly, or else, users should clean pipes' scale first. 
3.In central air-condition, before stop equipment working , users can add inhibitor help reduce corrosion on the equipment. 
4.Rain proof and dirt proof device will be used, if the equipment is installed outside. 
5. If pipe line is too long, users should make sure that there's a water treatment equipment at a distance, so that the function will be much more better.
6. There should be a 300mm free space room for easy to repair. Make sure to inspect if there's leak problem on the connections when equipment is finished installation.
7. When installed, the direction of flow rate should be the same as equipment. No reverse. Also drain valve and pipe need to installed at the drain.
8. Users not allowed to open the main frame. We will not in the charge of people death or hurt by high pressure Electricity.
 
 
How to use
-Red indicator light is the power indicator light.
-Green light is working indicator light.
-Red and green light is light on, it means equipment work Well.
 
 
How to deal with breakdown
Normally inspect according to the situation of red and green indicator light.
1)Red indicator light is the power indicator light. Green light is working indicator light.
2)Red light works, green light not work, users should stop the equipment, and notice the factory or technicians to repair.
3)Green light works, red light not work, it shows equipment in normal operation, users can notice the factory to repair at the same time.

                                     Welcome To Inquire, We Will Offer You The Best Items ! High-quality Speciality Electronic Water Descaler Machine


Application 

The electric descaler widely used in central air conditioning system, industry chilling system, heat exchange system, boiler system, etc.
 
Product structure 

It consists of main and vice part, which can be installed together or separated. Main part is a high-frequency signal generator, vice part can transfer signal to water.
 
Working principle

1.scale resist and prevent
Based on Electromagnetic Theory, invented by Dr. Lorentz, the electric water descaler stops calcium carbonate and magnesium carbonate formation. Water absorbs electromagnetic energy, which physical structure changes and chain water molecules break into smaller single water molecule. The single water molecule covers negative and positive ion of dissolve saline, which reduces electrostatic attraction and effective collision, but increase water dipole moment and compatibility to negative and positive saline, which finally loose pipe wall scale and to remove them.

2.kill bacterial and algae 
The electromagnetic wave creates turbulence flow, which destroys cell wall's ion channel and changes cell's living ambient. Cells die as of no suitable living area. What's more, large amount of single water molecules covers dissolve oxygen, which cut microorganism oxygen demanding so that to prevent microorganism sediment formation.

3. rust resist and corrosion prevention
Oxygen molecule in water become inert oxygen as covered by singe water molecule, which cut off oxygen-demanding for mental rust. 
The electromagnetic field create "Skin-effect", which gathers negative charge inside pipeline wall. Water molecule covers positive charge, it rejects Fe ion dissolve from metal pipe. Negative charge on pipeline wall attract positive Fe ion to form Fe3O4 membrane.
Feature 
1.Make use of high-frequency electromagnetic technology in water treating, which can increase at least 30% work efficiency.
2.The technology can treat max water hardness of 700mg/L. ( in CaCO3)
3.The special alloy material can make use life time to 20years. 
4.Signal light shows electrode energy release enough or not. 
5.Extra add drain outlet, which is easy to drain scales.
 
 
Technical parameter 

1.Input power: 220V, 50HZ
2.Water hardness require: ≤700mg/L(CaCO3)
   Temperature: ≤95ºC
   Work pressure: 1.0MPa,1.6MPa
   Flow speed: ≤2.8m/s
3. Scale resist: ≥95%
    Bacterial killing: ≥95%
    Algae removing: ≥95%
    Reduce corrosion: reduce to 1/10 of origin
4. Function time: within 2 hours in after treating. Half-time is 1 hour. 
 
Compare 
 
 

No
Item Made by PEIDE Made by others company Instruction

1

Shielding mesh
 

 
Shielding mesh makes sure electrodes work separately, without any interruption 

 
 
No shied mesh

Increase efficiency 30%
2 Electrode material Alloy material Brass Life time 5-7times than brass
3 Circuit board and electrode connection way 
 
Makes use of shielding connection, it can transfer energy to electrodes fully

 
Connect directly, which will cause dis-connect after long using. No shielding design, which has interruption to other equipment.

Peide reduce the energy consumption to the lowest
4 In/outlet design Add extra guide plate No Peide design can transfer more stable electromagnetic energy
5 Transformer material Transformer works well even in severe ambient, (even in water) electric elements all imported Less ability in high temperature and high humidity ambient. Peide design can install indoor or outdoor
6 Protection setting on main part The special temperature design can ensure main part work less than 40ºC. Over 50ºC Main part life time increases 3-5times.
7 Drain design Yes No Peide design more completed.
8 Vice part inside treating  With phosphorization treating No Increase strength of magnetic field.



Model options
 

Model 
Pipe diameter A B C D
Power

Water Flow

inch
mm W T/H
CLDC-2D 2 50 500 100 280 300 25 19
CLDC-2.5D 2.5 65 500 100 280 300 25 28
CLDC-3D 3 80 500 150 330 300 50 50
CLDC-4D 4 100 500 150 330 300 50 80
CLDC-5D 5 125 600 219 340 400 70 125
CLDC-6D 6 150 680 273 350 400 70 180
CLDC-8D 8 200 800 325 470 500 80 320
CLDC-10D 10 250 850 377 530 550 120 490
CLDC-12D 12 300 920 426 560 600 210 710
CLDC-14D 14 350 970 478 560 650 250 1000
CLDC-16D 16 400 1020 530 660 700 330 1400
CLDC-18D 18 450 1090 630 730 750 410 1600
CLDC-20D 20 500 1200 720 830 800 500 1970

 Attentions
1.Water equipment should be installed before equipment that need protect. It will be better to close to pump. All recycling water should flow into water treatment equipment fist.
2.If there's no big default and scales on old system, water treatment equipment can be installed directly, or else, users should clean pipes' scale first. 
3.In central air-condition, before stop equipment working , users can add inhibitor help reduce corrosion on the equipment. 
4.Rain proof and dirt proof device will be used, if the equipment is installed outside. 
5. If pipe line is too long, users should make sure that there's a water treatment equipment at a distance, so that the function will be much more better.
6. There should be a 300mm free space room for easy to repair. Make sure to inspect if there's leak problem on the connections when equipment is finished installation.
7. When installed, the direction of flow rate should be the same as equipment. No reverse. Also drain valve and pipe need to installed at the drain.
8. Users not allowed to open the main frame. We will not in the charge of people death or hurt by high pressure Electricity.
 
 
How to use
-Red indicator light is the power indicator light.
-Green light is working indicator light.
-Red and green light is light on, it means equipment work Well.
 
 
How to deal with breakdown
Normally inspect according to the situation of red and green indicator light.
1)Red indicator light is the power indicator light. Green light is working indicator light.
2)Red light works, green light not work, users should stop the equipment, and notice the factory or technicians to repair.
3)Green light works, red light not work, it shows equipment in normal operation, users can notice the factory to repair at the same time.

                                     Welcome To Inquire, We Will Offer You The Best Items !

Automatic Type Oil Distillation Plant

The Waste Engine Oil Distillation Plant is used to refine waste engine oil, crude oil and fuel oil after pyrolysis process into diesel grade oil, gasoline or and base oil. The daily capacity of this plant is about 5-6 tons.

 Waste Engine Oil Distillation Plant

Flow-chat of waste engine oi Distillation Plant

Waste Engine Oil Distillation Plant

Advantage of waste engine oi distillation plant

1. Unique and original manufacturing and technology with our own formula of our equipments in China;

2. Unique horizontal design, high oil output with about 90% oil yield and 100% conversion rate, highly effective and profitable;

3. Good quality end product oil as the substitution of standard diesel oil in usage;

Automatic submerged welding technology, ultrasonic nondestructive testing, both manual and the automatic safety devices;

4. Sync gas recycling system: fully burned after recycling and utilization, saving fuel and preventing pollution;

5. National patent, unique heat insulation shell: high efficiency temperature keeping, excellent energy-saving effect;

6. High condensing efficiency condensers with more oil output. Good quality oil, longer lifetime, and easy to clean;

7. National patent water film smoke scrubbers: efficient removal of the acid gas and dust of the smoke, environmental friendly to meet related national standards.

 

Technical Parameter of Waste engine Oil Distillation Plant

NO.

Item

Technical Parameter

1

Suitable Raw Materials

Waste engine oil, Pyrolysis fuel oil, crude oil

2

Structure

Horizontal Type

3

Capacity(24 hours)

3.5-6.5Mt

4

Work Pressure

Normal Pressure

5

Oil Yield

80%-90%

6

Power

18 kw/H

7

Cooling Method

Cycle water

8

Condensers

4 pieces of Vertical condensers

9

Emission Treatment

New DE-sulfurization Smoke Scrubbers

10

Heating Method

Hot Air

11

Type of Installation

With Foundation

12

Noise dB(A)

≤85

13

Dimension of Reactor(mm)

Ф2200×6000

Ф2500×8800

14

Operating Mode

Semi-continuous Operation

15

Main Chamber Weight (MT)

10~13Mt

16

Total Weight(MT)

25~35Mt

17

Installation Space Required

35m*15m

18

End Product

Non-standard diesel oil

19

Manpower

1~2/shift

20

Shipment Requirement

2*40HC=Ф2200×6000

1*40HC+1*40FR=Ф2500×8800

 

Automatic Type Oil Distillation Plant

Automatic Type Oil Distillation Plant,Automatic Type Waste Oil Distillation Plant,Used Engine Oil Refining Machine,Automatic Waste Oil Distillation Plant

Shangqiu Jinpeng Industrial Co., Ltd. , https://www.recyclings.nl